Complete portfolio for craniomaxillofacial reconstructions, combining precision, stability, and aesthetic excellence.
With an innovative spirit and constant focus on quality, Osteomed offers complete solutions for neurosurgical and craniomaxillofacial procedures, combining technology, precision, and safety in every detail...
The OSA – Supra Orthognathic Advancement System is a compact module with pre-curved plate configurations for rigid fixation of Le Fort I osteotomies, bilateral sagittal osteotomies, and genioplasty procedures.
A variety of special plates that enable product traceability, safer and faster fixation, plates with different shapes that meet the most demanding needs of surgeons...
Indicated for cranioplasty, craniosynostosis, craniotomy, and midline fractures, the 1.2 system features high-precision self-drilling screws and plates with a 0.55 mm profile, identified by their yellow color.
System 1.6 is indicated for cases such as cranioplasty, craniotomy, midface fractures, Lefort I, II, and III, and maxillary segmentation. The plates have a profile of 0.55–0.65 mm and are identified by their white color.
Angled plate and screw system, registered in Brazil since 2020, indicated for oral and maxillofacial and orthognathic surgeries. It allows for up to 20° of angulation when inserting the screw, eliminating the need for bend protectors and facilitating anatomical adaptation...
This system is indicated for jaw fractures, maxillary fixation, Lefort I, II, and III, BSSO (bilateral sagittal split osteotomy), mentoplasty, and segmental osteotomy.
System of special plates and non-absorbable screws for mini and microfragments, allowing screws to be inserted at angles of up to 20°...
Logic™ Jr. is an intraoral mandibular distractor designed for pediatric patients, including newborns. It enables the safe and gradual correction of mandibular deformities, with a design adapted to delicate bone structures.
Logic™ is an intraoral mandibular distractor used for gradual mandibular lengthening, aiding in the treatment of conditions such as a small jaw and facial asymmetries. Designed to follow the natural growth of the bone, it offers precision and control throughout the process.
Developed to offer practicality, safety, and efficiency in minimally invasive arthroscopic procedures of the temporomandibular joint, Techtools disposables guarantee high performance and reliability in each surgical step...
The NEXUS 2.7mm system is designed for arthroscopic procedures that require larger surgical instruments, offering precision, extended reach, and the ability to perform advanced interventions.
The NEXUS 1.8mm combines microinstruments and maximum precision, making it ideal for delicate procedures and hard-to-reach areas, while maintaining stability and efficient visualization.
NEXUS 1.9mm is a high-performance system for minimally invasive diagnostic and therapeutic arthroscopy, ideal for precise visualization and initial intra-articular maneuvers.
OMNIPORE® DUROMAX® Orbital Implants are intended for non-weight bearing applications in maxillofacial reconstruction and orbital bone structure repair, including the walls, floor, rims, and roof of the orbit. OMNIPORE DUROMAX Orbital Implants are available in four configurations containing medical grade titanium.
Composition based on the combination of different polymers, allowing the system to be adapted to the specific clinical needs of each patient...
The ASSEFIX ATM Anchor System integrates advanced materials and proven technologies into a complete, safe, and reliable solution designed to optimize surgical performance and clinical outcomes...
Osteomed – Oral and Maxillofacial Surgery – Implants, plates, and screws for oral and maxillofacial and cranial surgery.
With an innovative spirit and constant focus on quality, Osteomed offers complete solutions for neurosurgical and craniomaxillofacial procedures, combining technology, precision, and safety in every detail.
The OSA – Supra Orthognathic Advancement System is a compact module with pre-curved plate configurations for rigid fixation of Le Fort I osteotomies, bilateral sagittal osteotomies, and genioplasty procedures.
Pre-curved maxillary plates allow for advances of up to 12 mm, and preformed reinforcement plates minimize the need for contouring. Double-row BSSO plates are configured for advances of 6 mm to 14 mm.
ISO chin plates are designed for advances from 4 mm to 12 mm.
A variety of special plates that enable product traceability, safer and faster fixation, and plates with different shapes that meet the most discerning needs of surgeons.
Indicated for cranioplasty, craniosynostosis, craniotomy, and midline fractures, the 1.2 system features high-precision self-drilling screws and plates with a 0.55 mm profile, identified by their yellow color.
System 1.6 is indicated for cases such as cranioplasty, craniotomy, midface fractures, Lefort I, II, and III fractures, and maxillary segmentation. The plates have a profile of 0.55–0.65 mm and are identified by their white color.
Angled plate and screw system, registered in Brazil since 2020, indicated for oral and maxillofacial and orthognathic surgeries. It allows for up to 20° of angulation when inserting the screw, eliminating the need for bend protectors and facilitating anatomical adaptation. It enables 100% intraoral surgery, reducing surgical time and the risk of infection, as well as allowing for safe deviation of nerves and roots.
This system is indicated for jaw fractures, maxillary fixation, Lefort I, II, and III, BSSO (bilateral sagittal split osteotomy), mentoplasty, and segmental maxillary osteotomy with plates ranging from 0.60 to 1.1 mm in profile. It is identified by the color blue.
System of special plates and non-absorbable screws for mini and microfragments, allowing screws to be inserted at angles of up to 20°.
Indicated for fracture fixation, mandibular reconstruction, and surgical procedures involving osteotomies, trauma, and orthognathic reconstruction.
Logic™ Jr. is a pediatric intraoral mandibular distractor designed for use in patients under 4 years of age, including newborns. The system features straight or curved bars and is adapted to smaller, more delicate anatomies.
The device is secured using 1.2-mm screws, which are suitable for children’s bone structure, ensuring stability with minimal tissue trauma. As with the adult version, the activation mechanism uses a threaded wire operated by a hex key, allowing for controlled distraction of up to 25 mm.
It is indicated for stabilization, lengthening, and/or bone transport in cases of congenital deformities or post-traumatic defects of the mandible (ramus, body, symphysis, and alveolar ridge). The system is for single-use only and is not reusable or reprocessable.
Logic™ is an intraoral mandibular distractor designed for osteogenic mandibular distraction procedures. The system consists of straight or curved bars, allowing for adaptation to the patient’s anatomy and the desired distraction vector.
Bone fixation is achieved using 1.6 mm or 2.0 mm screws, ensuring stability throughout the procedure. The activation mechanism uses a threaded wire operated by a hex key, allowing for precise control of distraction, with an extension capacity of up to 25 mm.
The device is indicated for the correction of mandibular deformities, such as micrognathia and hemifacial microsomia, promoting gradual and predictable bone growth while respecting the natural trajectory of the mandible.
Developed to offer practicality, safety, and efficiency in minimally invasive arthroscopic procedures of the temporomandibular joint, Techtools disposables guarantee high performance and reliability in each surgical step.
Manufactured with quality materials and precision, they ensure a stable, predictable, and safe procedure, contributing to faster recovery and less tissue trauma. The line consists of three product levels, which are tailored to the complexity of each procedure:
With their functional design, Techtools disposables provide efficiency, safety, and consistent results in minimally invasive TMJ procedures.
The NEXUS 2.7mm system is designed for arthroscopic procedures that require larger surgical instruments, offering precision, extended reach, and the ability to perform advanced interventions.
System advantages:
The NEXUS 1.8mm combines microinstruments and maximum precision, making it ideal for delicate procedures and hard-to-reach areas, while maintaining stability and efficient visualization.
Facilitates procedures such as:
The instrumental microarchitecture provides high control and versatility in minimally invasive surgeries.
NEXUS 1.9mm is a high-performance system for minimally invasive diagnostic and therapeutic arthroscopy, ideal for precise visualization and initial intra-articular maneuvers.
Especially indicated for:
It is the versatile and compact option for procedures requiring minimal tissue aggression.
It has a 1.8mm → 2.7mm transition system, increasing surgical versatility.
OMNIPORE® DUROMAX® Orbital Implants are intended for non-weight-bearing applications in maxillofacial reconstruction and orbital bone structure repair, including walls, floor, rims, and roof of the orbit.
These are available in four configurations, consisting of a grade 2 unalloyed titanium (ASTM F67) structure encapsulated by a porous high-density polyethylene (HDPE) structure.
Features of OMNIPORE DUROMAX Orbital Implants include:
Provide radiographic visibility
Greater contour retention
Anatomical shape
Mounting hole positions allow for the placement of screws
Two thicknesses: 1.0 mm and 1.5 mm
Compatibility with 1.6 mm titanium screws
Composition based on a combination of different polymers, allowing the system to be tailored to the specific clinical needs of each patient.
2.0 mm system
The ASSEFIX ATM Anchor System integrates advanced materials and proven technologies into a complete, safe, and reliable solution designed to optimize surgical performance and clinical outcomes.
Its composition and design provide high biocompatibility, biostability, and postoperative control, combining intraoperative practicality with predictable results. It is a solution designed to meet the needs of the surgeon, with an absolute focus on patient safety.
Key differentiators